BSWA309 Class 2 Integrating Sound Level Meter
Special Discount:
50% Discount
Category:
Sound Level Meter
Quantity: Out of Stock
We will send you a notification as soon as this product is available again.
BSWA308 Sound Level Meters
BSWA 308/BSWA 309 are octave sound level meters updating the dual-core (DSP+ARM) architecture to single chip ARM with float point unit, and updating all fix-point calculation to float-point, which signif cantly improves the accuracy and stability. Re-design analog front end circuit also lower the noise floor and linear range of product.BSWA 308 is Class 1 and BSWA 309 is Class 2. Both instruments have certificated by the China CPA (Certification of Pattern Approval) and CMC (China Metrology Certification).
Single chip high speed ARM with FPU | USB port function implemented |
White backlight LCD | Update firmware via USB (also power supply) |
Integral period from 1s~24h | Timer feature support auto measurement |
0.1s, 0.2s, 0.5s logger step added | Internal GPS (option) with GPS timing |
5 templates to save user setting | Single range to cover 123dB dynamic range |
B-weighting added to meet ANSI standard | Reduce the noise floor (only for Class 1) |
Automatic power on with external supply, ease of integration | Upper limit of measurement: 136dBrms/139dBpeak (40mV/Pa) |
Product Features:
● Class 1 (BSWA 308) and Class 2 (BSWA 309) sound level meter
● Comply with IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997
● 1/1 Octave in accordance with IEC61260-1:2014 and ANSI S1.11-2004
● Linearity range: 20dBA~134dBA (Class 1), 25dBA~136dBA (Class 2)
● Single range to cover 123dB/122dB dynamic range
● Frequency weighting A/B/C/Z. Time weighting Fast/Slow/Impulse
● 3 profile calculation in parallel with different frequency/time weighting. 14 custom define measurement
● Calculate SPL, LEQ, Max, Min, Peak, SD, SEL, E
● LN statistics and time history curve display
● User def ne integral period measurement, integral period up to 24h
● High speed ARM core with FPU (Float Point Unit) to achieve wide frequency response, large dynamic range and low noise floor
● 4G MicroSD card (TF card) mass storage
● RS-232 remote control port
● Mini thermal printer for measurement data print
● Internal GPS module (option), support GPS timing.
Technical Parameters:
Type | Accuracy | Standard | Octave | 1/1 Octave, Centre Frequencies: 31.5Hz to 16kHz GB/T 3241-2010 Class 1, IEC 61260-1:2014 Class 1 ANSI S1.11-2004 Class 1 | ||||||||
MPA231T: 1/2” prepolarized measurement microphone, Class 1. Sensitivity: 50mV/Pa. Frequency Range: 10Hz~20kHz. | ||||||||||||
TNC connecter with ICCP power supply (4mA/24V) | ||||||||||||
Fully float-point digital signal processing (digital detector and filterIntegral Period | Measurement Functions | 24h Measurement | Frequency Weighting | Time Weighting | Self-noise | Upper Limit | Frequency Response | Linearity Range | Dynamic Range | Peak C Range | Range Setting | Single range to cover whole dynamic range |
24Bits | ||||||||||||
48kHz | ||||||||||||
Time domain noise curve display. Duration time: 1min, 2min, 10min | ||||||||||||
160x160 LCD with white backlight, 14 step contrast level | ||||||||||||
4G MicroSD card (TF card) | ||||||||||||
Post-processing software VA-SLM can read, analyze and generate reports of store data | ||||||||||||
Directly connect to the computer to read the memory card (USB disk) | ||||||||||||
AC (max 5VRMS output), DC (10mV/dB), RS-232 serial interface and USB virtual serial port | ||||||||||||
User define alarm threshold. LED indicate the alarm status | ||||||||||||
4x1.5V alkaline batteries (LR6/AA/AM3), sustainable use of more than 10 hours. It also can be supply by external DC power (7V-14V 500mA) and USB power (5V 1A) | ||||||||||||
Built-in backup battery has been calibrated at factory to the error <26s in 30days (<10ppm, 25±16℃). It can keep RTC running when replacing the main batteries. GPS timing function available (option with GPS module) | ||||||||||||
Update firmware via USB port | ||||||||||||
Temperature: -10℃~ 50℃. Humidity: 20% ~ 90%RH | ||||||||||||
Real-time temperature display on the main screen | ||||||||||||
W70 x H300 x D36 | ||||||||||||
Approx. 620g, including 4 alkaline batteries | ||||||||||||
Receiver Type: 50 Channels; Time-To-First-Fix: Cold Start 27s, Warm Start 27s, Hot Start 1s; Sensitivity: Tracking -161dBm, Reacquisition -160dBm, Cold Start -147dBm, Hot Start -156dBm; Horizontal position accuracy: 2.5m, Timing accuracy: 30ns, Velocity accuracy: 0.1m/s; Update Rate: 1Hz, Operation Limits: Dynamic≤4g, Altitude<50000m, Velocity<500m/s | ||||||||||||
CA111, Class 1, 94dB/114dB, 1kHz | ||||||||||||
Mini thermal printer, RS-232 port |